48290000 - DIRIS B-30 RS485 Modbus 230VAC | Socomec

48290000


  Download
    General information
  • Product Range: DIRIS B-30
  • Long Description: DIRIS B-30 RS485 Modbus 230VAC
  • Short Description: DIRIS B-30 RS485 Modbus 230VAC
    Certificates and declaration
  • Conformity to standard #3: CEC Compliant
  • Conformity to standard #4: E257746 Vol.X5 Sec.A7
  • Proposition 65 California: WARNING This product can expose you to chemicals including bisphenol A (BPA), which is known to the State of California to cause birth defects or reproductive harm. For more information go to : www.P65Warnings.ca.gov
    Container Information
  • EAN13: 3596032773083
  • Package Level 1 Gross Weight: 0.22
  • Package Level 1 Length: 0.08
  • Package Level 1 Units: B
  • Package Level 1 Width: 0.06
    Main
  • Reference: 48290000
    General product characteristics
  • Device type: Multifunction Power metering and monitoring device (PMD)
    Ordering
  • Country of origin: FR
    Standards and regulations
      Accuracy
    • ANSI C12.20: Class 0.2
      Electromagnetic compatibility
    • Immunity to conducted disturbances: 400A/m LEVEL IV
    • Immunity to electrical fast transients/bursts: LEVEL IV
    • Immunity to electrostatic discharges on contact: LEVEL III
    • Immunity to electrostatic fields in the air: LEVEL III
    • Immunity to power frequency magnetic fields: CLASS B
    • Immunity to radiated electromagnetic fields: LEVEL IV
    • Surge immunity in common mode: LEVEL III
      PMD
    • IEC 61557-12: Class 0.5 for the global measurement chain
      Safety
    • Safety standards: IEC/EN 61010-1
      UL 61010-1
      CAN/CSA C22.2 No. 61010-1
    • UL file number: E257746
      Safety standard
    • UL product category: PICQ/PICQ7
    Technical characteristics
      Communication characteristics
    • Communication Ports: RS485 output
    • Communication Protocols: Modbus RTU
    • Communication speed: 1200-115200 bauds
    • Physical layer: RS485 2-3 half duplex wires - SELV
    • USB port interface: 1 Type B micro USB; Upgrade and configuration of the module
      Electrical characteristics
    • Device power consumption (VA): ≤ 2
    • Input voltage: 110-230 VAC +/- 15%
    • Power supply connection: Removable spring-cage terminal, 2 x 2 positions, 0.5 … 2.5 mm² solid cable or 0.25 … 1.5 mm² stranded cable with ferrule
    • Power supply frequency: 50/60 Hz
    • Power supply type: AC
      Environnement
    • Relative humidity: 55 °C / 131 °F / 97% RH (IEC 60068-2-30)
    • Storage temperature: -25 … +85 °C (IEC 60068-2-1/IEC 60068-2-2)
      Environmental characteristics
    • Impact resistance: Front panel: 5J - casing: 1J (IEC 61010-1 Ed 3.0)
    • Maximum operating altitude: 6560 feet / 2000 m
    • Operating temperature: -10 … +70 °C / +14 °F … +158 °F (IEC 60068-2-1/IEC 60068-2-2)
    • PEP ecopassport - ISO 14025: SOCO-2014-01-v1-fr, SOCO-2014-01-v1-en
    • Vibration: 0.35 mm, 25 Hz, 20 min/axe (IEC 61557-12)
      General characteristics
    • Display compatibility: DIRIS D-30
      DIRIS Digiware D-50
      DIRIS Digiware D-70
    • Webserver compatibility: WEBVIEW-M
      WEBVIEW-L
      Measurement characteristics
    • Active Energy accuracy: Class 0.2 ANSI C12.20
      Class 0.5 for the global measurement chain according to IEC 61557-12 from 2% up to 120% of the rated current (with TE/TF sensors)
    • Active Power accuracy: Class 0.2 ANSI C12.20
      Class 0.5 for the global measurement chain according to IEC 61557-12 from 2% up to 120% of the rated current (with TE/TF sensors)
    • Alarms: 8 alarms with configurable thresholds (low/high)
    • Current measurement type: AC
    • Digital input function: To be configured in device:
      Logical status
      Position of protection device or drawer (open/closed)
      Trip status
      Pulse metering
      Synchronisation pulse
    • Digital input type: Optocoupler internal polarisation (12 VDC ± 10 %) or external polarisation (10-30VDC ± 10%)
    • External sensors association: TE Solid Core; TR/iTR split Core; TF Flexible
    • Frequency accuracy: Class 0.02
    • Frequency range: 45-65 Hz
    • Frequency rating: 50/60 Hz
    • General measurements: Metering:
      +/- kWh, +/- kvarh, kVAh
      Multi-tariff (8 max)
      Load curves

      Multi-measurement:
      V1, V2, V3, U12, U23, U31, f
      I1, I2, I3, In, ∑P, ∑Q, ∑S, ∑PF
      P, Q, S, PF per phase
      Predictive Power
      Voltage Ph/N unbalance
      Voltage Ph/Ph unbalance
      Current unbalance (Inba, Idir, Iinv, Ihom, Inb)
      Phi, cos Phi, tan Phi
    • Load type: To be configured in the module:
      1P+N - 1CT
      2P - 1CT
      2P+N - 2CT
      3P - 1CT
      3P - 2CT
      3P - 3CT
      3P+N - 1CT
      3P+N - 3CT
    • Measurement level: Power Quality Analysis
    • Measurement updating period: Configurable from 200ms to 60s
    • Network type: To be configured in the module:
      1P+N
      2P
      2P+N
      3P
      3P+N
    • Number of current inputs: 4
    • Number of Digital inputs/outputs: 2 Digital inputs
    • Power Quality measurements: THD V1, V2, V3, U12, U23, U31, I1, I2, I3
      Individual harmonics U, V, I (up to 63rd)
      Voltage sags, swells, interruptions, current inrush
    • Pulse counter: Yes, 2 Digital inputs
    • Reactive Energy accuracy: Class 2 for the global measurement chain with TE, TR or TF current sensors
    • Voltage connection: Removable spring-cage terminal, 2 x 6 positions, 0.5 … 2.5 mm² solid cable or 0.25 … 1.5 mm² stranded cable with ferrule
    • Voltage measurement accuracy: Class 0.2
    • Voltage measurement range Ph/N: 50-300 VAC
    • Voltage measurement range Ph/Ph: 87-520 VAC
    • Voltage measurement type: AC
    • Voltage Sampling rate: 9.6 kHz
    • Voltage transformer: Optional
    • Voltage transformer primary: To be configured
    • Voltage transformer secondary: To be configured
  • Dimensions: 3 modules wide (54mm)