48290129 - DIRIS Digiware I-43 Current | Socomec

48290129


  Download
    General information
  • Product Range: DIRIS Digiware I
  • Long Description: DIRIS Digiware I-43 Current; Current measurement module for DIRIS Digiware system; 4; Monitoring
  • Short Description: DIRIS Digiware I-43 Current
    Certificates and declaration
  • Conformity to standard #3: CEC Compliant
  • Conformity to standard #4: -
  • Proposition 65 California: WARNING This product can expose you to chemicals including bisphenol A (BPA), which is known to the State of California to cause birth defects or reproductive harm. For more information go to : www.P65Warnings.ca.gov
    Container Information
  • EAN13: 3596032833695
  • Package Level 1 Gross Weight: 0.0
  • Package Level 1 Length: 0.3
  • Package Level 1 Width: 0.145
    Main
  • Reference: 48290129
    General product characteristics
  • Device type: Current measurement module for DIRIS Digiware system
    Ordering
  • Country of origin: FR
    Standards and regulations
      Accuracy
    • ANSI C12.20: Class 0.2
      PMD
    • IEC 61557-12: Class 0.5 for the global measurement chain
      Safety
    • Safety standards: IEC/EN 61010-1
      UL 61010-1
      CAN/CSA C22.2 No. 61010-1
    • UL file number: E257746
      Safety standard
    • UL product category: PICQ/PICQ7
    Technical characteristics
      Communication characteristics
    • Communication Ports: RJ45 Digiware bus input output
    • USB port interface: 1 Type B micro USB; Upgrade and configuration of the module
      Electrical characteristics
    • Device power consumption (VA): 1.125
      Environnement
    • Relative humidity: 55 °C / 131 °F / 97% RH (IEC 60068-2-30)
    • Storage temperature: -25 … +70 °C / -13 °F … + 158 °F (IEC 60068-2-1/IEC 60068-2-2)
      Environmental characteristics
    • Impact resistance: Front panel: 1J - casing: 1J (IEC 61010-1 Ed 3.0)
    • Maximum operating altitude: 6560 feet / 2000 m
    • Operating temperature: -10 … +70 °C / +14 °F … +158 °F (IEC 60068-2-1/IEC 60068-2-2)
    • PEP ecopassport - ISO 14025: SOCO-2014-06-v1-fr, SOCO-2014-06-v1-en
    • Vibration: 0.35 mm, 25 Hz, 20 min/axe (IEC 61557-12)
      General characteristics
    • Display compatibility: DIRIS D-30
      DIRIS Digiware D-40
      DIRIS Digiware D-50
      DIRIS Digiware D-70
    • Webserver compatibility: WEBVIEW-M
      WEBVIEW-L
      Measurement characteristics
    • Active Energy accuracy: Class 0.2 ANSI C12.20
      Class 0.5 for the global measurement chain according to IEC 61557-12 from 2% up to 120% of the rated current (with TE/TF sensors)
    • Active Power accuracy: Class 0.2 ANSI C12.20
      Class 0.5 for the global measurement chain according to IEC 61557-12 from 2% up to 120% of the rated current (with TE/TF sensors)
    • Current measurement type: AC
    • Current module input: RJ12
    • Digital input connection: Removable screw terminal, AWG 15 to AWG 35 or 0.14 to
      1.5 mm² stranded or solid cable
    • Digital input function: To be configured in module:
      Logical status
      Position of protection device or drawer (open/closed)
      Trip status
      Pulse metering
    • Digital input type: Non-insulated input, internal polarisation 12VDC max, 1mA
    • Digital output connection: Removable screw terminal, AWG 10 to AWG 32 or 0.2 to 2.5 mm²
      stranded or solid cable
    • Digital output function: To be configured in module:
      Remote command of device
      Alarm report
      Load shedding
    • Digital output type: Relay output: 230VAC +/- 15% - 1A
    • External sensors association: TE Solid Core; TR/iTR split Core; TF Flexible
    • General measurements: Metering:
      +/- kWh, +/- kvarh, kVAh

      Multi-measurement:
      I1, I2, I3, In, ∑P, ∑Q, ∑S, ∑PF
    • Load type: To be configured in the module:
      1P+N - 1CT
      2P - 1CT
      2P+N - 2CT
      3P - 1CT
      3P - 2CT
      3P - 3CT
      3P+N - 1CT
      3P+N - 3CT
    • Measurement level: Monitoring
    • Measurement updating period: Configurable from 200ms to 60s
    • Number of current inputs: 4
    • Number of Digital inputs/outputs: 2 Digital inputs / 2 Digital outputs
    • Power Quality measurements: THD I1, I2, I3, In
    • Reactive Energy accuracy: Class 2 for the global measurement chain with TE, TR or TF current sensors
  • Dimensions: 1.5 modules wide (27mm)