Fill rate E-Order Common | 83 |
---|---|
Fill rate E-Order Selection | 80 |
Certificates and Declaration
Conformity to standard #1 | UL98 |
---|---|
Conformity to standard #2 | CSA-C22.2 No. 4 |
Conformity to standard #3 | Class 4651 02 |
Proposition 65 California | WARNING This product can expose you to chemicals including Styrene, which is known to the State of California to cause cancer. For more information go to: www.P65Warnings.ca.gov |
Standards
Conformity to standards | UL |
---|
Certificates and Declaration - Safety
UL file number | E201138 |
---|
Technical Characteristics
Fuse size | J |
---|---|
Number of poles | 2 |
Rated current [A] | 200 |
Type | I-0-Test |
Frame size | 6 |
Technical Characteristics - Connection terminals
Max. connection section / AWG | 300MCM |
---|---|
Min. connection section / AWG | #6 |
Technical Characteristics - Environmental
Operating temperature | -4 ... +122°F / -20 ... +50°C |
---|---|
Storage temperature | -40 ... +158°F / -40 ... +70°C |
Technical Characteristics - Max. motor HP
DC FLA motor max. / 125 VDC | 15/112 |
---|---|
DC FLA motor max. / 250 VDC | 40/140 |
FLA 1 ph motor max. / 120 VAC | 15/135 |
FLA 1 ph motor max. / 220-240 VAC | 40/176 |
FLA 1 ph motor max. / 240 VAC | 40/176 |
FLA 3 ph motor max. / 220-240 VAC | 60/154 |
FLA 3 ph motor max. / 440-480 VAC | 125/156 |
FLA 3 ph motor max. / 600 VAC | 150/144 |
Technical Characteristics - Mechanical
Endurance (number of operating cycles) | 8000 |
---|---|
Operating torque [lbs.in/Nm] | 90/10.2 |
Technical Characteristics - Short-circuit capacity
Auxiliary contacts / Electrical characteristics | A600 |
---|---|
Max fuse rating [A] | 200 |
Operation voltage 2 P - 3/4 P | 600VAC |
Short circuit rating at 600 VAC [kA] | 200 |
Type of fuse | J |
UL General use rating | 200 |
ETIM - Electrical characteristics
Max. rated operation voltage Ue AC [V] | 600 |
---|---|
Rated permanent current Iu [A] | 200 |
Rated operation power at AC-23, 400 V [kW] | 220 |
Conditioned rated short-circuit current Iq [kA] | 50 |
Number of poles | 2 |
ETIM - Mechanical characteristics
Cable entry | Top/bottom |
---|---|
Equipped with connectors | No |
Suitable for floor mounting | Yes |
Suitable for front mounting | Yes |
Suitable for busbar mounting | No |
Degree of protection (IP), front side | IP20 |
ETIM - Technical features
Version as main switch | Yes |
---|---|
Version as safety switch | Yes |
Suitable for fuses | Other |
With error protection | No |
Type of electrical connection of main circuit | Bolt connection |
Type of control element | Long turning handle |
Position control element | Front side |
Motor drive optional | No |
Motor drive integrated | No |
Version as emergency stop installation | Yes |
Logistics
GTIN/EAN | 3596031934850 |
---|---|
Customs number | 8536309090 |
Price unit | PC |
Weight of the packing unit | 2.6 |
Length of the packing unit | 0.016 |
Width of the packing unit | 0.025 |
Depth of the packing unit | 0.024 |
Product Details
Effective date | 2008-08-25 |
---|---|
Country of origin | FR |
Discount Policy | 1CC50 |
Discount Policy Label | FUSERBLOC UL |
Length of the product unit | 0.195 |
Width of the product unit | 0.1462 |
Depth of the product unit | 0.13 |
Weight | 2.6 |
Classification
UNSPSC | 39122233 |
---|---|
ETIM Class | EC001040 |
IGCC | 5291 |