U3Ryb25nIFBvaW50cw==
RnVuY3Rpb24=
=-=-=-=-=-=- System =-=-=-=-=-=-
Fill rate E-Order Common | 83 |
---|---|
Fill rate E-Order Selection | 62 |
Certificates and Declaration
Conformity to standard #1 | UL1008 & UL98 |
---|---|
Conformity to standard #2 | CSA-C22.2 No. 4 Class 4651-02 |
Proposition 65 California | WARNING This product can expose you to chemicals including Styrene, which is known to the State of California to cause cancer. For more information go to: www.P65Warnings.ca.gov |
Standards
Conformity to standards | UL |
---|
Certificates and Declaration - Safety
UL file number | E317092 and E201138 |
---|
Technical Characteristics
Number of poles | 4 |
---|---|
Rated current [A] | 600 |
Technical Characteristics - Connection terminals
Max. connection section / AWG | 2X 600MCM |
---|---|
Min. connection section / AWG | 2X #2 |
Technical Characteristics - Environmental
Operating temperature | -4 ... +122°F / -20 ... +50°C |
---|---|
Storage temperature | -40 ... +158°F / -40 ... +70°C |
Technical Characteristics - Mechanical
Endurance (number of operating cycles) | 3050 |
---|---|
Operating torque [lbs.in/Nm] | 327.5 / 37 |
Technical Characteristics - Short-circuit capacity
Auxiliary contacts / Electrical characteristics | AC300 |
---|---|
Max fuse rating [A] | 800 for UL1008 and 600 for UL98 |
Operation voltage 2 P - 3/4 P | -/600 |
Rated operational current / 240 VAC resistive load | 600 |
Rated operational current / 240 VAC “Total System” | 400 |
Rated operational current / 480 VAC resistive load | 600 |
Rated operational current / 480 VAC “Total System” | 350 |
Rated operational current / 600 VAC resistive load | 600 |
Rated operational current / 600 VAC “Total System” | - |
Short circuit rating at 600 VAC with “Any Breaker” (kA) / Short circuit capacity | 50 |
Short circuit rating at 600 VAC with “Any Breaker” (kA) / Short circuit rating | 35 |
Short circuit rating at 600 VAC [kA] | 100 |
Type of fuse | L for UL1008 and J for UL98 |
ETIM - Electrical characteristics
Max. rated operation voltage Ue AC [V] | 600 |
---|---|
Rated operating voltage [V] | 240..600 |
Rated permanent current Iu [A] | 600 |
Number of poles | 4 |
ETIM - Mechanical characteristics
Suitable for floor mounting | No |
---|---|
Suitable for front mounting 4-hole | No |
Suitable for front mounting centre | No |
Suitable for distribution board installation | No |
Suitable for intermediate mounting | Yes |
Colour control element | Black |
Degree of protection (IP), front side | IP20 |
ETIM - Technical features
Version as main switch | Yes |
---|---|
Version as maintenance-/service switch | Yes |
Version as safety switch | Yes |
Version as emergency stop installation | No |
Version as reversing switch | Yes |
Number of switches | 2 |
Motor drive optional | No |
Motor drive integrated | No |
Voltage release optional | No |
Device construction | Built-in device fixed built-in technique |
Type of control element | Door coupling rotary drive |
Interlockable | Yes |
Type of electrical connection of main circuit | Bolt connection |
Logistics
GTIN/EAN | 3596031869565 |
---|---|
Customs number | 8536508090 |
Price unit | PC |
Weight of the packing unit | 40 |
Length of the packing unit | 0.475 |
Width of the packing unit | 0.395 |
Depth of the packing unit | 0.3 |
Product Details
Effective date | 2007-03-19 |
---|---|
Country of origin | FR |
Discount Policy | 1CH37 |
Discount Policy Label | SIRCOVER UL |
Length of the product unit | 0.25 |
Width of the product unit | 0.466 |
Depth of the product unit | 0.347 |
Weight | 40 |
Classification
UNSPSC | 39122205 |
---|---|
ETIM Class | EC000216 |
IGCC | 5177 |