U3Ryb25nIFBvaW50cw==

  • UmVsaWFiaWxpdHkgYW5kIHBlcmZvcm1hbmNl

  • U2FmZXR5IG9mIHByb3BlcnR5IGFuZCBwZXJzb25uZWw=

  • U2ltcGxpY2l0eQ==

RnVuY3Rpb24=

U0lSQ08gbm9uLWZ1c2libGUgZGlzY29ubmVjdCBzd2l0Y2hlcyBhcmUgaGVhdnktZHV0eSBzd2l0Y2hlcyB0aGF0IGJyZWFrIGFuZCBtYWtlIHBvd2VyIGNpcmN1aXRzIG9uIGFuZCBvZmYtbG9hZCBjb25kaXRpb25zIGFuZCBwcm92aWRlIHNhZmUgaXNvbGF0aW9uLjxiciAvPg0KVGhlc2Ugc3dpdGNoZXMgYXJlIGV4dHJlbWVseSBkdXJhYmxlIGFuZCBhcmUgdGVzdGVkIGFuZCBhcHByb3ZlZCBmb3IgdXNlIGluIHRoZSBtb3N0IGRlbWFuZGluZyBhcHBsaWNhdGlvbnMu

Certificates and Declaration

Conformity to standard #1 UL98
Conformity to standard #2 CSA-C22.2 No. 4
Conformity to standard #3 IEC 60947-3
Proposition 65 California WARNING This product can expose you to chemicals including Styrene, which is known to the State of California to cause cancer. For more information go to: www.P65Warnings.ca.gov

Environmental Sustainability

Climate change - Total - Cradle to Grave [kg CO₂ eq.] 541
Climate change - Total - Cradle to Gate [kg CO₂ eq.] 37
SVHC > 0.1 mass percentage? No
RoHS applicable? Yes

Standards

Conformity to standards
  • IEC
  • UL

Certificates and Declaration - Safety

UL file number E201138

Technical Characteristics

Height [mm] 260
Width [mm] 230
Depth [mm] 128
Weight [kg] 6
Control operator Direct : B2, J1 / External : S2
Number of poles 3
Rated voltage 600 VAC
Rated current [A] 400
Type Front operation
Frame size B5

Technical Characteristics - Connection terminals

Max. connection section / AWG 2x 350 / 600MCM
Min. connection section / AWG 2x #6 / #4

Technical Characteristics - Environmental

Operating temperature -4 ... +122°F / -20 ... +50°C
Storage temperature -40 ... +158°F / -40 ... +70°C

Technical Characteristics - Max. motor HP

DC FLA motor max. / 125 VDC [Hp/A] 20/148
DC FLA motor max. / 250 VDC [Hp/A] 50/173
FLA 3 ph motor max. / 220-240 VAC [Hp/A] 125/312
FLA 3 ph motor max. / 440-480 VAC [Hp/A] 250/302
FLA 3 ph motor max. / 600 VAC [Hp/A] 350/336

Technical Characteristics - Mechanical

Endurance (number of operating cycles) 6000
Operating torque [lbs.in/Nm] 128.3/14.5

Technical Characteristics - Short-circuit capacity

Auxiliary contacts / Electrical characteristics A300
Max fuse rating [A] 400
Operation voltage 2 P - 3/4 P 600VAC
Short circuit rating at 600 VAC [kA] 200
Type of fuse J
UL General use rating [A] 400

ETIM - Electrical characteristics

Max. rated operation voltage Ue AC [V] 600
Rated operating voltage [V] 240..600
Rated permanent current Iu [A] 400
Rated operation power at AC-23, 400 V [kW] 220
Switching power at 400 V [kW] 220
Number of poles 3

ETIM - Mechanical characteristics

Suitable for floor mounting No
Suitable for front mounting 4-hole Yes
Suitable for front mounting centre No
Suitable for distribution board installation No
Suitable for intermediate mounting Yes
Colour control element Other
Degree of protection (IP), front side IP20
Width [mm] 230
Height [mm] 260
Depth [mm] 128

ETIM - Technical features

Version as main switch Yes
Version as maintenance-/service switch Yes
Version as safety switch Yes
Version as emergency stop installation Yes
Version as reversing switch No
Number of switches 1
Motor drive optional No
Motor drive integrated No
Voltage release optional No
Device construction Built-in device fixed built-in technique
Type of control element Other
Interlockable Yes
Type of electrical connection of main circuit Bolt connection

Logistics

GTIN/EAN 3596031963768
Customs number 8536508000
Price unit PC
Weight of the packing unit [kg] 6
Length of the packing unit [m] 0.44
Width of the packing unit [m] 0.355
Depth of the packing unit [m] 0.21

Product Details

Effective date 2009-05-26
Offer Life Cycle Code 40
Country of origin FR

Classification

UNSPSC 39122233
ETIM Class EC000216
IGCC 5290

Documentation

  • PDF
    SIRCO UL98 400A
    Select
  • PDF
    SIRCO UL 98 - Non-fusible switches standards UL and CSA
    Select
  • PDF
    CALIFORNIA PROPOSITION 65 WARNING SIRCO M
    Select
  • PDF
    SIRCO UL98 100A - 200A
    Select
  • PDF
    SIRCO UL98 600A-1200A
    Select
  • SIRCO 3X400A F CAD 27003041