Strong Points
-
Multi-circuit
-
Accurate
-
Flexible
-
Compact
-
Plug & Play
-
Cutting-edge technologies
Function
DIRIS Digiware I modules are DIN-rail mounted power monitoring modules. Associated with DIRIS Digiware U voltage measurement modules, they measure and monitor parameters such as powers, energies and power quality of electrical installations. Due to their design, they can be installed at the closest point to the circuit to measure.
The RJ12 current inputs allow a quick and error free connection to current sensors with automatic detection of the sensor's primary rating, current flow direction to ensure reliable measurements at all times.
Adding DIRIS Digiware I modules to the bus is done simply by clicking in an RJ45 cable. This allows great flexibility to users who wish to add more metering points in the future.
Conformity to standard #1 | UL 61010-1 Guide PICQ File E257746 |
---|---|
Conformity to standard #2 | CSA-C22.2 No. 61010-1 |
Conformity to standard #3 | IEC 61557-12 |
Conformity to standard #4 | ISO 14025 |
Proposition 65 California | WARNING This product can expose you to chemicals including bisphenol A (BPA), which is known to the State of California to cause birth defects or reproductive harm. For more information go to : www.P65Warnings.ca.gov |
Conformity to standards |
|
---|
Safety standards | IEC/EN 61010-1 UL 61010-1 CAN/CSA C22.2 No. 61010-1 |
---|---|
UL file number | E257746 |
Device type | Current acquisition modules |
---|
Application | Analysis |
---|---|
Model | I-45 |
Number of current inputs | 4 |
Type | Current acquisition module |
Maximum operating altitude | 6560 feet / 2000 m |
---|---|
Operating temperature | -10°C … +70°C |
Storage temperature | -13 to +158 °F / -25 to +70 °C |
Accuracy class | Class 0.2 DIRIS Digiware class only, Class 0.5 with TE, iTR or TF sensors, Class 1 with TR sensors |
---|---|
Degree of Pollution | 2 |
General measurements | Metering - ± kWh, ± kvarh, kVAh, Demand profiles ,Multi-tariff, Multi-measurement - I1, I2, I3, In, ΣP, ΣQ, ΣS, ΣPF , P, Q, S, PF per phase ,Predictive power, Current unbalance (Inba, Idir, Iinv,, Ihom, Inb) , Phi, cos Phi, tan Phi, |
Number of Digital inputs/outputs | 2 input/ 2 outputs |
Power Quality measurements | Quality - THDi1, THDi2, THDi3, THDin ,Individual harmonics I (up to 63rd),Overcurrents |
Voltage measurement type | AC |
Sampling frequency [Hz] | 10000 |
---|---|
Number of current measurement inputs | 4 |
Voltage type (supply voltage) | DC |
Supply voltage DC [V] | 0.24..0.24 |
Display resolution (horizontal) [px] | 350 |
Display resolution (vertical) [px] | 160 |
Number of digital inputs | 2 |
Number of digital outputs | 2 |
Supporting protocol for IEC 61850 Ethernet | No |
Supporting protocol for OPC UA PubSub | No |
Supporting protocol for PROFIBUS | No |
Supporting protocol for Modbus | Yes |
Supporting protocol for PROFINET IO | No |
Supporting protocol for other bus systems | No |
With audit logging (audit log) | No |
With firmware signature | Yes |
With logging of security events (security event log) | Yes |
With Role Based Access Control (RBAC) | No |
Web server with HTTPS transfer protocol | No |
Width [mm] | 27 |
---|---|
Height [mm] | 150 |
Depth [mm] | 72 |
Degree of protection (IP), front side | IP20 |
Ampere meter | Yes |
---|---|
Blind power meter | Yes |
With rotational speed meter | No |
Frequency meter | No |
Pulse counter | No |
Voltmeter | No |
Effective power measurement device | Yes |
Remote display | Yes |
GTIN/EAN | 3596032783860 |
---|---|
Customs number | 9030900000 |
Price unit | PC |
Weight of the packing unit | 0.18 |
Length of the packing unit | 0.165 |
Width of the packing unit | 0.065 |
Depth of the packing unit | 0.055 |
Effective date | 2014-01-23 |
---|---|
Country of origin | FR |
Discount Policy | 1EN60 |
Discount Policy Label | MEASUREMENT SYSTEM PACKAGE |
UNSPSC | 83101808 |
---|---|
ETIM Class | EC002301 |
IGCC | 6042 |