U3Ryb25nIFBvaW50cw==

  • U2FmZSBhbmQgcmVsaWFibGU=

  • UGx1ZyAmIFBsYXkgZGVzaWdu

  • QWNjdXJhdGU=

RnVuY3Rpb24=

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

General Product Characteristics

Device type Enclosed single-point submeter

Technical Characteristics

Height [mm] 304.8
Width [mm] 254
Depth [mm] 152.4
ANSI C12.20 Class 0.2 Meter Accuracy
IEC 61557-12 Class 0.5 system accuracy (Meter + CTs)
Power Monitoring Device Inside DIRIS B-30
USB Port Interface 1 Micro USB Type B - Configuration via Easy Config System and firmware upgrade via Product Upgrade Tool
Voltage Measure Type AC
Communication ports RS485
Communication protocols Modbus RTU
Material Polycarbonate
Rated frequency 45-65 Hz

Technical Characteristics - Environmental

Enclosure Protection Degree NEMA 4X

Technical Characteristics - Measurement

Frequency rating 50/60 Hz
General measurements Energy Metering:
+/- kWh, +/- kvarh, kVAh

Multi-measurement:
Amps, Volts, Frequency
∑P, ∑Q, ∑S, ∑PF
P, Q, S, PF per phase
Voltage unbalance
Current unbalance
Power Quality measurements Sag/Swell/Interruption detection; THD & Individual Harmonics; Unbalance
Frequency Range 45-65 Hz
Frequency Accuracy Class 0.02
Voltage Measure Range Ph-N 50-300VAC
Voltage Measure Range Ph-Ph 87-520VAC
Voltage Measure Accuracy Class 0.2
Voltage Transformer Optional
Network Type Configurable: 1P+N 2P 2P+N 3P 3P+N
Measure Level Power Monitoring
Load Type Configurable: 1P+N - 1CT 2P - 1CT 2P+N - 2CT 3P - 1CT 3P - 2CT 3P - 3CT 3P+N - 1CT 3P+N - 3CT
External Sensors Association TE Solid Core; TR/iTR Split Core; TF Flexible Rogowski
Alarms Under/Over Measurement Alarms
Number of Three-Phase Metering Points 1
Number of Single-Phase Metering Points 4
Active Energy Accuracy Class 0.2 Meter accuracy ANSI C12.20; Class 0.5 system accuracy (Meter + CT) according to IEC 61557-12 from 2% up to 120% of the rated current (with TE/iTR/TF sensors)

Technical Characteristics - Mechanical

Onboard Display NO

Logistics

Customs number 9030320000
Price unit PC

Product Details

Description Enclosed single-point submeter; DIRIS DigiBOX B-30; 110-240VAC power supply; no display; 1 metering point/4 CT channels; Polycarbonate NEMA 4X enclosure; RS485 communication
Effective date 2022-06-15
Offer Life Cycle Code 40
Country of origin US
Eco Contribution yes

Classification

UNSPSC 83101808
ETIM Class EC002301
IGCC 6042

Documentation

  • PDF
    DIRIS DigiBOX - Enclosed single & multi-point metering solution
    Select
  • PDF
    Finding the right power meter
    Select
  • PDF
    Selection Guide - UL_CSA Power Monitoring
    Select
  • PDF
    How to comply with submetering requirements of IECC_ASHRAE 90.1 energy codes?
    Select
  • PDF
    Selection Guide - UL_CSA Power Monitoring
    Select
  • PDF
    BROCHURE – DIRIS DIGIBOX RANGE
    Select

References

DIRIS DigiBOX B is also available in 1 version

Item Communication protocols Communication ports Select
USDBPB30ND0 Modbus RTU RS485