U3Ryb25nIFBvaW50cw==
-
RnVsbHkgaW50ZWdyYXRlZA==
-
QSB3aWRlIHJhbmdlIG9mIGFjY2Vzc29yaWVz
-
VXBncmFkZWFiaWxpdHk=
-
Q29tcGxpYW5jZSB3aXRoIG1ham9yIGNlcnRpZmljYXRpb25zIGFuZCBhcHByb3ZhbHM=
RnVuY3Rpb24=
Certificates and Declaration
Conformity to standard #1 | UL98 |
---|---|
Conformity to standard #2 | CSA |
Conformity to standard #3 | Class 4651 02 |
Proposition 65 California | WARNING This product can expose you to chemicals including Formaldehyde, which is known to the State of California to cause cancer. For more information go to: www.P65Warnings.ca.gov |
Standards
Conformity to standards |
|
---|
Certificates and Declaration - Safety
UL file number | E201138 |
---|
Technical Characteristics
Length of the product unit [mm] | 189 |
---|---|
Width of the product unit [mm] | 78 |
Depth of the product unit [mm] | 75 |
Weight [kg] | 0.63 |
Control operator | Direct : M01 / External : S00, S0, S01 |
Number of poles | 3 |
Rated voltage | 600 VAC |
Rated current [A] | 60 |
Type | Rotary |
Frame size | M3 |
Technical Characteristics - Connection terminals
Max. connection section / AWG | 2/0 or 2x#1 |
---|---|
Min. connection section / AWG | #10 or 2x#10 |
Technical Characteristics - Environmental
Operating temperature | -4 ... +122°F / -20 ... +50°C |
---|---|
Storage temperature | -40 ... +158°F / -40 ... +70°C |
Technical Characteristics - Max. motor HP
FLA 3 ph motor max. / 220-240 VAC [Hp/A] | 20/54 |
---|---|
FLA 3 ph motor max. / 440-480 VAC [Hp/A] | 40/52 |
FLA 3 ph motor max. / 600 VAC [Hp/A] | 50/52 |
Technical Characteristics - Mechanical
Endurance (number of operating cycles) | 10000 |
---|---|
Operating torque [lbs.in/Nm] | 12.4/1.4 |
Technical Characteristics - Short-circuit capacity
Auxiliary contacts / Electrical characteristics | A300 |
---|---|
Max fuse rating [A] | 60 |
Operation voltage 2 P - 3/4 P | 600VAC |
Short circuit rating at 600 VAC [kA] | 100 |
Type of fuse | J |
UL General use rating [A] | 60 |
ETIM - Electrical characteristics
Max. rated operation voltage Ue AC [V] | 690 |
---|---|
Rated operating voltage [V] | 400..690 |
Rated permanent current Iu [A] | 60 |
Rated permanent current at AC-23, 400 V [A] | 60 |
Rated permanent current at AC-21, 400 V [A] | 60 |
Rated short-time withstand current lcw [kA] | 2.75 |
Rated operation power at AC-23, 400 V [kW] | 60 |
Switching power at 400 V [kW] | 60 |
Conditioned rated short-circuit current Iq [kA] | 50 |
Number of poles | 3 |
ETIM - Mechanical characteristics
Suitable for floor mounting | No |
---|---|
Suitable for front mounting 4-hole | No |
Suitable for front mounting centre | No |
Suitable for distribution board installation | Yes |
Suitable for intermediate mounting | Yes |
Colour control element | Other |
Degree of protection (IP), front side | IP20 |
ETIM - Technical features
Version as main switch | Yes |
---|---|
Version as maintenance-/service switch | Yes |
Version as safety switch | Yes |
Version as emergency stop installation | Yes |
Version as reversing switch | No |
Number of switches | 1 |
Motor drive optional | No |
Motor drive integrated | No |
Voltage release optional | No |
Device construction | Built-in device fixed built-in technique |
Type of control element | Other |
Interlockable | Yes |
Type of electrical connection of main circuit | Screw connection |
Logistics
GTIN/EAN | 3596031973743 |
---|---|
Customs number | 8536508000 |
Price unit | PC |
Weight of the packing unit [kg] | 0.63 |
Length of the packing unit [m] | 0.17 |
Width of the packing unit [m] | 0.1 |
Depth of the packing unit [m] | 0.09 |
Product Details
Effective date | 2009-09-07 |
---|---|
Offer Life Cycle Code | 40 |
Country of origin | CN |
Classification
UNSPSC | 39122233 |
---|---|
ETIM Class | EC000216 |
IGCC | 5290 |