U3Ryb25nIFBvaW50cw==

  • U3RhYmxlIHBvc2l0aW9ucw==

  • Q29tcGFjdCBkZXNpZ24=

  • T24tbG9hZCBzd2l0Y2hpbmc=

  • UmVsaWFiaWxpdHk=

RnVuY3Rpb24=

U0lSQ09WRVIgYXJlIGhlYXZ5LWR1dHkgbWFudWFsIHRyYW5zZmVyIHN3aXRjaGVzLiBUaGV5IGVuc3VyZSBzd2l0Y2hpbmcgdHJhbnNmZXIgb2Ygc291cmNlcyBvciB0cmFuc2ZlciBvZiB0d28gbG93IHZvbHRhZ2UgY2lyY3VpdHMgb24gbG9hZCBhcyB3ZWxsIGFzIHRoZWlyIHNhZmUgZGlzY29ubmVjdGlvbi48YnIgLz4NClRoZXNlIGV4dHJlbWVseSBkdXJhYmxlwqBzd2l0Y2hlcyBhcmUgdGVzdGVkIGFuZCBhcHByb3ZlZCBmb3IgdXNlIGluIHRoZSBtb3N0IGRlbWFuZGluZyBhcHBsaWNhdGlvbnMsIHN1Y2ggYXMgcmVzaXN0aXZlIGxvYWQgb3IgdG90YWwgc3lzdGVtIGFwcGxpY2F0aW9ucy4=

Certificates and Declaration

Conformity to standard #1 UL1008 & UL98
Conformity to standard #2 CSA-C22.2 No. 4 Class 4651-02
Proposition 65 California WARNING This product can expose you to chemicals including Styrene, which is known to the State of California to cause cancer. For more information go to: www.P65Warnings.ca.gov

Environmental Sustainability

PEP Filename SOCO-00076-V01.01-EN.pdf
Climate change - Total - Cradle to Grave [kg CO₂ eq.] 648
Climate change - Total - Cradle to Gate [kg CO₂ eq.] 398

Standards

Conformity to standards UL

Certificates and Declaration - Safety

UL file number E317092 and E201138

Technical Characteristics

Length of the product unit [mm] 250
Width of the product unit [mm] 622
Depth of the product unit [mm] 346.5
Weight [kg] 47
Number of poles 4
Rated current [A] 800

Technical Characteristics - Connection terminals

Max. connection section / AWG 2X 600MCM
Min. connection section / AWG 2X #2

Technical Characteristics - Environmental

Operating temperature -4 ... +122°F / -20 ... +50°C
Storage temperature -40 ... +158°F / -40 ... +70°C

Technical Characteristics - Mechanical

Endurance (number of operating cycles) 3050
Operating torque [lbs.in/Nm] 442.5 / 50

Technical Characteristics - Short-circuit capacity

Auxiliary contacts / Electrical characteristics AC300
Max fuse rating [A] 1000 for UL1008 and 800 for UL98
Operation voltage 2 P - 3/4 P -/600
Rated operational current / 240 VAC resistive load [A] 800
Rated operational current / 240 VAC “Total System” [A] 700
Rated operational current / 480 VAC resistive load [A] 800
Rated operational current / 480 VAC “Total System” [A] 600
Rated operational current / 600 VAC resistive load [A] 800
Rated operational current / 600 VAC “Total System” [A] -
Short circuit rating at 600 VAC with “Any Breaker” (kA) / Short circuit capacity [ms] 50
Short circuit rating at 600 VAC with “Any Breaker” (kA) / Short circuit rating [kA] 35
Short circuit rating at 600 VAC [kA] 100
Type of fuse L

ETIM - Electrical characteristics

Max. rated operation voltage Ue AC [V] 600
Rated operating voltage [V] 240..600
Rated permanent current Iu [A] 800
Number of poles 4

ETIM - Mechanical characteristics

Suitable for floor mounting No
Suitable for front mounting 4-hole No
Suitable for front mounting centre No
Suitable for distribution board installation No
Suitable for intermediate mounting Yes
Colour control element Black
Degree of protection (IP), front side IP20

ETIM - Technical features

Version as main switch Yes
Version as maintenance-/service switch Yes
Version as safety switch Yes
Version as emergency stop installation No
Version as reversing switch Yes
Number of switches 2
Motor drive optional No
Motor drive integrated No
Voltage release optional No
Device construction Built-in device fixed built-in technique
Type of control element Door coupling rotary drive
Interlockable Yes
Type of electrical connection of main circuit Bolt connection

Logistics

GTIN/EAN 3596031869589
Customs number 8536508000
Price unit PC
Weight of the packing unit [kg] 47
Length of the packing unit [m] 0.8
Width of the packing unit [m] 0.6
Depth of the packing unit [m] 0.73

Product Details

Effective date 2007-03-19
Offer Life Cycle Code 40
Country of origin FR

Classification

UNSPSC 39122205
ETIM Class EC000216
IGCC 5177

Resources & Documentation