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

General Product Characteristics

Device type Enclosed multi-point submeter
Datalogging Yes

Technical Characteristics

Height [mm] 304.8
Width [mm] 304.8
Depth [mm] 167.64
ANSI C12.20 Class 0.2 Meter Accuracy
IEC 61557-12 Class 0.5 system accuracy (Meter + CTs)
Power Monitoring Device Inside DIRIS Digiware
USB Port Interface 1 Micro USB Type B - Configuration via Easy Config System and firmware upgrade via Product Upgrade Tool
Voltage Measure Type AC
Communication ports RS485; Ethernet
Communication protocols Modbus RTU; Modbus TCP; BACnet IP; SNMP v1, v2, v3; FTP(S)
Material Steel
Rated frequency 45-65 Hz

Technical Characteristics - Environmental

Enclosure Protection Degree NEMA 12/3R

Technical Characteristics - Measurement

Frequency rating 50/60 Hz
General measurements Energy Metering:
+/- kWh, +/- kvarh, kVAh

Multi-measurement:
Amps, Volts, Frequency
∑P, ∑Q, ∑S, ∑PF
P, Q, S, PF per phase
Frequency Range 45-65 Hz
Frequency Accuracy Class 0.02
Voltage Measure Range Ph-N 50-300VAC
Voltage Measure Range Ph-Ph 87-520VAC
Voltage Measure Accuracy Class 0.2
Voltage Transformer Optional
Network Type Configurable: 1P+N 2P 2P+N 3P 3P+N
Measure Level Metering
Load Type Configurable: 1P+N - 1CT 2P - 1CT 2P+N - 2CT 3P - 1CT 3P - 2CT 3P - 3CT 3P+N - 1CT 3P+N - 3CT
External Sensors Association TE Solid Core; TR/iTR Split Core; TF Flexible Rogowski
Alarms Under/Over Measurement alarm on kW, kvar, kVA only
Number of Three-Phase Metering Points 4
Number of Single-Phase Metering Points 12
Active Energy Accuracy Class 0.2 Meter accuracy ANSI C12.20; Class 0.5 system accuracy (Meter + CT) according to IEC 61557-12 from 2% up to 120% of the rated current (with TE/iTR/TF sensors)

Technical Characteristics - Mechanical

Onboard Display YES, DIRIS Digiware D-50

Logistics

Customs number 9030320000
Price unit PC

Product Details

Description Enclosed multi-point submeter; DIRIS DigiBOX M4; D-50 display; 4 metering points/12 CT channels; Steel NEMA 12/3R enclosure; RS485 + Ethernet communication
Effective date 2022-06-15
Offer Life Cycle Code 40
Country of origin US
Eco Contribution yes

Classification

UNSPSC 83101808
ETIM Class EC002301
IGCC 6042

Documentation

  • PDF
    DIRIS DigiBOX M PRO with D-70
    Select
  • PDF
    DIRIS DigiBOX M with D-50
    Select
  • PDF
    DIRIS DigiBOX - Enclosed single & multi-point metering solution
    Select
  • PDF
    Finding the right power meter
    Select
  • PDF
    Selection Guide - UL_CSA Power Monitoring
    Select
  • PDF
    How to comply with submetering requirements of IECC_ASHRAE 90.1 energy codes?
    Select
  • PDF
    DIRIS DigiBOX M Enclosed multi-point submetering solution
    Select
  • PDF
    Selection Guide - UL_CSA Power Monitoring
    Select
  • PDF
    BROCHURE – DIRIS DIGIBOX RANGE
    Select
  • PDF
    COMMISSIONING GUIDE - DIRIS DigiBOX M with D-50
    Select
  • PDF
    COMMISSIONING GUIDE - DIRIS DigiBOX M PRO with D-70
    Select